Provided by 360 Compliance

FCC IDF5316PG9914

Granted to Tyco Safety Products Canada Ltd. on 2022-07-14

Class II Permissive Change

Grant details

FCC ID
F5316PG9914
Grantee
Tyco Safety Products Canada Ltd.
Grantee code
F5316What is this?
Product code
PG9914What is this?
Product name
Wireless Digital Pet Immune PIR Detector
Equipment class
DSS · Part 15 Spread Spectrum Transmitter
Grant date
2022-07-14
Application purpose
Class II Permissive Change
Product category
Radio frequency devices How categories work
Frequency range
912.75-919.108 MHz
Address
Concord, Ontario, L4K 4L2, Canada
Application ID
BHRyJF0ox3uJ+l0YlailEw==
Documents

What this grant means

On 2022-07-14 the FCC issued an equipment authorization grant to Tyco Safety Products Canada Ltd. for FCC ID F5316PG9914. A Class II Permissive Change means the grantee changed a device already certified under this FCC ID in a way that affects characteristics reported in the original application. New test data was filed and the FCC ID stays the same.

F5316Grantee code, assigned by the FCC
PG9914Product code, chosen by the grantee

Equipment authorization

Frequency (MHz)Output powerToleranceEmission designatorRules
912.75–919.108 0.031 15C

Application information

Responsible party
Dan Nita, dan.nita@jci.com, 1-416-357-1409
Technical contact
Michael Nikishin, Hermon Laboratories Ltd., nikishin@hermonlabs.com, 972 4626 8440
Non-technical contact
Dan Nita, Tyco Safety Products Canada Ltd., dnita@tycoint.com, 1-647-480-0430
Test firm
George Shleimovich, Hermon Laboratories Ltd., mail@hermonlabs.com, +972 4 626 8469
TCB email
certification@telefication.com
TCB scope
A4: UNII devices & low power transmitters using spread spectrum techniques
Long-term confidentiality
Yes
Short-term confidentiality
Yes
Short-term release date
01/11/2023
Modular equipment
Does not apply
Composite device
No
Cognitive radio
No
Authorization waiver
No
Authorization waiver approved
No
Section 5301 certification
Yes
Related OET Knowledge DataBase Inquiry
No

Applications 2

  • 2022-07-14 Class II Permissive Change BHRyJF0ox3uJ+l0YlailEw==
  • 2017-02-22 Change in Identification qycjgbN0qcwGzIwW60aDpg==

Grant of authorization

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:
  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 07/14/2022

Application Dated: 07/14/2022
Tyco Safety Products Canada Ltd.
3301 Langstaff Road
Concord, Ontario, L4K 4L2
Canada
 
Attention: Dan Nita , Approvals Manager
NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F5316PG9914
Name of Grantee:  Tyco Safety Products Canada Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Wireless Digital Pet Immune PIR Detector
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 912.75  -  919.108 0.031  
Class II Permissive Change : The changes are (a) To upgrade operational amplifier, (b) to add new antenna, (c) firmware modification and (d) other minor changes.

Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Documents 15

View on fcc.gov ↗ (opens in a new tab)

FCC.gov blocks direct links from other sites (referer check), so the titles below are not clickable. Use “View on fcc.gov” above to open and download the actual files.

  • Block DiagramMetadata only
    Block Diagram · PDF 121 KB
  • C2PC_letter_to_FCC
    Cover Letter(s) · Available 2022-07-14 · PDF 65.3 KB
  • Cover_letter
    Cover Letter(s) · Available 2022-07-14 · PDF 180.7 KB
  • Declaration_of_authorization
    Cover Letter(s) · Available 2022-07-14 · PDF 136.4 KB
  • Request_for_confidentiality
    Cover Letter(s) · Available 2022-07-14 · PDF 64.3 KB
  • External Photos
    External Photos · Available 2022-07-14 · PDF 70.7 KB
  • ID Label/Location Info
    ID Label/Location Info · Available 2022-07-14 · PDF 68.6 KB
  • Internal Photos
    Internal Photos · Available 2023-01-11 · PDF 242.6 KB
  • Operational DescriptionMetadata only
    Operational Description · PDF 139.6 KB
  • RFExp
    RF Exposure Info · Available 2022-07-14 · PDF 70.5 KB
  • SchematicsMetadata only
    Schematics · PDF 121.6 KB
  • Test Report
    Test Report · Available 2022-07-14 · PDF 1.9 MB
  • Test Setup Photos
    Test Setup Photos · Available 2022-07-14 · PDF 365.7 KB
  • Users Manual-1
    Users Manual · Available 2022-07-14 · PDF 144.2 KB
  • Users Manual-2
    Users Manual · Available 2022-07-14 · PDF 1.1 MB

Block diagram, schematics and operational description are held confidential at the applicant’s request, so the FCC does not publish them. Why are some documents confidential?

360Compliance

Need help with FCC certification or global market access?