Regulatory Testing from Start to Certificate

← Back to list

FCC ID XUJCRP719A

Professional Diagnostic Tool — by Launch Tech Co., Ltd.

Device Details

FCC IDXUJCRP719A
Grantee CodeXUJCR
Product CodeP719A
ApplicantLaunch Tech Co., Ltd.
AddressNo.4012, Launch Industrial Park, North Wuhe Rd, Bantian Street, Longgang District,, Shenzhen, N/A, 518129, China
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionProfessional Diagnostic Tool
Application PurposeOriginal Equipment
Grant Date2026-09-13
Frequency Range5180-5240 MHz; 5260-5320 MHz; 5500-5720 MHz; 5745-5825 MHz; 2402-2480 MHz; 2412-2462 MHz

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180–5240 MHz Original Equipment 2026-09-13
5260–5320 MHz Original Equipment 2026-09-13
5500–5720 MHz Original Equipment 2026-09-13
5745–5825 MHz Original Equipment 2026-09-13

Exhibits (37) View on FCC.gov ↗

FCC.gov blocks direct links from other sites (referer check) — titles below aren't clickable. Use "View on FCC.gov" above to open and download the actual files.

DocumentTypeAvailableFile
SAR Appendix B RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 1.6 MB
SAR Appendix C_1 RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 5.3 MB
SAR Appendix C_2 RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 4.2 MB
SAR Appendix C_3 RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 4.4 MB
SAR Appendix C_4 RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 4.6 MB
SAR Appendix C_5 RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 4.5 MB
SAR Appendix C_6 RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 5 MB
SAR Appendix C_7 RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 5.3 MB
SAR Appendix C_8 RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 5.2 MB
SAR Test Report RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 995.4 KB
Schematics Metadata only Schematics ADOBE ACROBAT PDF 1.1 MB
Software Security Description Metadata only SDR Software/Security Info. ADOBE ACROBAT PDF 224.4 KB
Test Report_5G Wi-Fi_1 Test Report 2026-09-13 ADOBE ACROBAT PDF 5.5 MB
Test Report_5G Wi-Fi_2 Test Report 2026-09-13 ADOBE ACROBAT PDF 5.3 MB
Test Report_5G Wi-Fi_3 Test Report 2026-09-13 ADOBE ACROBAT PDF 5.5 MB
Test Report_5G Wi-Fi_4 Test Report 2026-09-13 ADOBE ACROBAT PDF 5.3 MB
Test Report_5G Wi-Fi_5 Test Report 2026-09-13 ADOBE ACROBAT PDF 5.3 MB
Test Report_5G Wi-Fi_6 Test Report 2026-09-13 ADOBE ACROBAT PDF 5.4 MB
Test Report_5G Wi-Fi_7 Test Report 2026-09-13 ADOBE ACROBAT PDF 5.4 MB
Test Report_5G Wi-Fi_8 Test Report 2026-09-13 ADOBE ACROBAT PDF 925.5 KB
FCC 15E DFS Report Test Report 2026-09-13 ADOBE ACROBAT PDF 1.3 MB
Antenna Specification Test Report 2026-09-13 ADOBE ACROBAT PDF 1.2 MB
SAR Test Setup Photos Test Setup Photos 2026-09-13 ADOBE ACROBAT PDF 564.3 KB
Test Setup Photos Test Setup Photos 2026-09-13 ADOBE ACROBAT PDF 1.6 MB
User Manual Users Manual 2026-09-13 ADOBE ACROBAT PDF 1.5 MB
Attestation Statements part 2.911 d 5i and d 5ii Attestation Statements 2026-09-13 ADOBE ACROBAT PDF 137.2 KB
US AGENT Letter Attestation Statements 2026-09-13 ADOBE ACROBAT PDF 62.1 KB
SDoC Attestation Letter Attestation Statements 2026-09-13 ADOBE ACROBAT PDF 183.8 KB
Block Diagram Metadata only Block Diagram ADOBE ACROBAT PDF 177 KB
Confidentiality Letter Cover Letter(s) 2026-09-13 ADOBE ACROBAT PDF 90.9 KB
Model Difference Letter Cover Letter(s) 2026-09-13 ADOBE ACROBAT PDF 136.6 KB
Authority Letter Cover Letter(s) 2026-09-13 ADOBE ACROBAT PDF 116.8 KB
External Photos External Photos 2026-09-13 ADOBE ACROBAT PDF 1.2 MB
Label Location ID Label/Location Info 2026-09-13 ADOBE ACROBAT PDF 154 KB
Internal Photos Internal Photos 2026-09-13 ADOBE ACROBAT PDF 1.1 MB
Operation Description Metadata only Operational Description ADOBE ACROBAT PDF 116.2 KB
SAR Appendix A RF Exposure Info 2026-09-13 ADOBE ACROBAT PDF 265.7 KB

Application Information

Application IDjYUxSBxNWT4vJtHHVHOoSw==
Final Action Date2026-09-13
Application PurposeOriginal Equipment
ModelP719A
Frequency Range5180-5240 MHz; 5260-5320 MHz; 5500-5720 MHz; 5745-5825 MHz; 2402-2480 MHz; 2412-2462 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionProfessional Diagnostic Tool
Responsible PartyIvy Zhong, lihua.zhong@cnlaunch.com, (86)755-84528007
Non-Technical ContactShichun Tao, Launch Tech (USA) Inc., shichun.tao@cnlaunch.com, (909) 698-8666
Test FirmLisa Wang, EMTEK (Shenzhen) Co., Ltd., wangli@emtek.com.cn, 8675526954280
TCB Emailcb@industrial-ia.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Long-Term ConfidentialityYes
Short-Term ConfidentialityNo
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications (1)

Application IDDatePurpose
jYUxSBxNWT4vJtHHVHOoSw== 2026-09-13 Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmission DesignatorRules
5180–5240 MHz 0.026 15E
5260–5320 MHz 0.016 15E
5500–5720 MHz 0.016 15E
5745–5825 MHz 0.023 15E

Grants

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:
  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 09/13/2026

Application Dated: 09/14/2026
Launch Tech Co., Ltd.
No.4012, Launch Industrial Park, North Wuhe Rd,
Bantian Street, Longgang District,
Shenzhen, 518129
China
 
Attention: Ivy Zhong , Manager
NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XUJCRP719A
Name of Grantee:  Launch Tech Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Professional Diagnostic Tool
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.026  
CC 15E 5260.0  -  5320.0 0.016  
CC 15E 5500.0  -  5720.0 0.016  
CC 15E 5745.0  -  5825.0 0.023  
Output Power listed is the maximum conducted output power. The highest reported SAR for body, product-specific (10g extremity) and simultaneous transmission exposure conditions are 0.75 W/kg, 0.30 W/kg and 0.97 W/kg, respectively. This device supports 20, 40 and 80 MHz bandwidth modes.
CC: This device is certified pursuant to two different Part 15 rules sections.

Get in touch to take the next step with 360Compliance

Contact us